您好,欢迎来到淘生意平台!请 |免费注册

产品展厅本站服务收藏该商铺

深圳市维信仪器仪表有限公司

免费会员
手机逛
深圳市维信仪器仪表有限公司

Product Display

产品展示

当前位置:深圳市维信仪器仪表有限公司>>福禄克FLUKE/NetAlly测试仪>>线缆测试仪>> dtx-laba/setFLUKE DTX Cat6A测试套件包DTX-LABA/SET

FLUKE DTX Cat6A测试套件包DTX-LABA/SET

产品二维码
参  考  价:面议
具体成交价以合同协议为准
  • 产品型号:dtx-laba/set
  • 品牌:
  • 产品类别:LAN/电信/电缆测试
  • 所在地:深圳市
  • 信息完整度:
  • 样本:
  • 更新时间:2021-04-07 17:07:57
  • 浏览次数:9
收藏
举报

联系我时,请告知来自 淘生意平台

深圳市维信仪器仪表有限公司

经销商

  • 经营模式:经销商
  • 商铺产品:695条
  • 所在地区:广东深圳市
  • 注册时间:2021-03-24
  • 最近登录:2021-10-25
  • 联系人:郭亮 (销售)
产品简介

FLUKE DTX Cat6A测试套件包DTX-LABA/SET
FLUKE DTX Cat6A测试套件包DTX-LABA/SET Fluke has received numerous requests to support Category 6A patch cord testing. In ANSI/TIA/EIA-568-B.2-10, limits have been set for t

详情介绍
Certifying category 6A patch cords using the DTX Laboratory Adapter
DTX Cat6A测试套件包DTX-LABA/SET
Fluke Networks has received numerous requests to support Category 6A patch cord testing. In ANSI/TIA/EIA-568-B.2-10, test limits have been set for the certification of Category 6A patch cords. The transmission requirements of the test jack to be used for certifying Category 6A patch cords has also been defined.

So why is there still no category 6A patch cord adapter from Fluke Networks?  The issue is the transmission performance requirements of the test jack. No connecting hardware vendor has a jack that meets these very specific requirements for Fluke Networks to use. 

In the interim, to help cable manufacturers produce very high quality category 6A patch cords, the following experimental solution is available.
This solution is intended for cabling manufacturers only. There is no technical support for these adapters. 
In addition to the DTX-LABA/SET, you will need the DTX-REFMOD to synchronize the main and remote units:
 
Selecting the test jack to use
With any given category 6A connector, the best channel performance will be achieved using a category 6A patch cord from the same vendor. It therefore makes sense to certify vendor A patch cord with vendor A jack. Jacks and plugs should be interoperable between vendors now that the RJ45 test plug has been defined in TIA/EIA-568-B.2-10; but it is recommended not to mix vendors when certifying patch cords with this solution. Please ensure you use the DTX-LABA/SR for the remote jack as shown below. It has 100 Ohm resistors on it to enhance the Return Loss accuracy of the measurement along with.

Vendors implementing this solution have told us the use of a bonded cable for this application is recommended to limit the impact on return loss. Alternative cables may be used if their impact on return loss is minimal. The wires from the jack to the circuit board should be as short as possible. In addition, the wires should lay on the PCB as much as possible as shown in Figure 2.

The number of insertions a jack can have will depend up on the vendor. Our experience has shown that you can expect around 5,000 insertions before the jack needs replacing. You can use the
counter in the DTX to monitor the life of the jack.

Software
Please ensure you have  and  installed on your PC. These contain the correct limits for ANSI/TIA/EIA-568-B.2-10.
FLUKE DTX Cat6A测试套件包DTX-LABA/SET
上一篇: FLUKE DTX-10GKIT 万兆铜缆测试包
下一篇: FLUKE NTS2-PRO网络万用表
我要评论
文明上网,理性发言。(您还可以输入200个字符)

所有评论仅代表网友意见,与本站立场无关。

请选择省份

  • 安徽
  • 北京
  • 福建
  • 甘肃
  • 广东
  • 广西
  • 贵州
  • 海南
  • 河北
  • 河南
  • 黑龙江
  • 湖北
  • 湖南
  • 吉林
  • 江苏
  • 江西
  • 辽宁
  • 内蒙古
  • 宁夏
  • 青海
  • 山东
  • 山西
  • 陕西
  • 上海
  • 四川
  • 天津
  • 新疆
  • 西藏
  • 云南
  • 浙江
  • 重庆
  • 香港
  • 澳门
  • 台湾
  • 国外
=
同类优质产品

在线询价

X

已经是会员?点击这里 [登录] 直接获取联系方式

会员登录

X

请输入账号

请输入密码

=

请输验证码

收藏该商铺

X
该信息已收藏!
标签:
保存成功

(空格分隔,最多3个,单个标签最多10个字符)

常用:

提示

X
您的留言已提交成功!我们将在第一时间回复您~