推荐选择型号:
xxkg | C3/C3MR/C4MR/A6S/A6M/B10S/B10M | BM6G-xx-xxkg-3B |
xxkg | C3/C3MR/C4MR/A6S/A6M/B10S/B10M | BM6G-xx-xxkg-3B-S1 |
20kg-500kg通过OIML C5级认证及NTEP A6S/A6M/B10S/B10M级认证 |
技术指标
额定载荷 | kg | 10/20/50/60/75/100/150/200/300/400/500/600 | |||
精度 | C3 | C4 | A6M | A6S | |
检定分度数 | n max | 3000 | 4000 | ||
小检定分度值 | v min | Emax/10000 | Emax/15000 | Emax/15000 | Emax/20000 |
综合误差 | (%FS) | ≤±0.0200 | ≤±0.0173 | ≤±0.0113 | ≤±0.009 |
蠕变 | (%FS/30min) | ≤±0.0245 | ≤±0.0184 | ≤±0.0184 | ≤±0.008 |
温度对输出灵敏度的影响 | (%FS/10℃) | ≤±0.0117 | ≤±0.0088 | ≤±0.0088 | ≤±0.006 |
温度对零点输出的影响 | (%FS/10℃) | ≤±0.0140 | ≤±0.0093 | ≤±0.0093 | ≤±0.007 |
输出灵敏度 | (mv/v) | 2.0±0.2 | |||
输入阻抗 | (Ω) | 10kg/20kg/50kgSE/75kgSE/100kgSE | 50kg-600kg | ||
380±15 | 350±3.5 | ||||
输出阻抗 | (Ω) | 350±3.5 | |||
绝缘阻抗 | (MΩ) | ≥5000(50VDC) | |||
零点输出 | (%FS) | ≤±2.0 | |||
温度补偿范围 | (℃) | -10~+40 | |||
允许使用温度范围 | (℃) | -35~+70 | |||
推荐激励电压 | (V) | 5~12(DC) | |||
激励电压 | (V) | 18(DC) | |||
安全过载范围 | (%FS) | 150 | |||
极限过载范围 | (%FS) | 300 | |||
推荐安装扭矩 | Nm | 10kg/20kg/50kgSE/75kgSE/100kgSE:10 | 50kg-600kg:20 | ||
防护等级 | IP68/IP69K | ||||
ATEX等级(可选) | II 1G Ex ia II 1C T4 | II 1D Ex iaD20 T73℃ | II3G Ex nL II C T4 |